• Preparation
    • Ensure patient is on a flat surface
    • Maintain spinal precautions if indicated
    • Remove any bulky clothing or objects over the pelvis
  • Landmarks and placement
    • Locate the greater trochanters—this is the correct level for binder application
    • Binder should not be placed over the iliac crests or abdomen
    • If unsure, err on the lower side—better to be slightly below than above
  • Application
    • Slide the binder under the patient using a log-roll or draw-sheet technique
    • Centre it over the greater trochanters
    • Pull both sides firmly to compress the pelvis and secure in place with Velcro or buckle
    • Compression should be snug but not so tight as to impair distal circulation
  • Post-application care
    • Reassess haemodynamics and limb neurovascular status
    • Check for any signs of skin pressure or compromised perfusion
    • Confirm position with pelvic X-ray if not already done
    • Leave binder in place until definitive pelvic stabilisation or exclusion of significant injury